Date: July 24, 1986
Number: 142
Title: PC-Net Shell Driver Correction
A problem has been found with the workstation shell driver for
Orchid Technology, Santa Clara Systems and AST PC-Net. The
problem appears when a workstation is running an application such as
Word Perfect or Lotus 123. If the workstation is left without any
activity for five to ten minutes while running either of those
applications, the workstation will hang, leaving all the files open on
the server. In order to clear the hang the station must be re-booted.
This problem is corrected by replacing the "SHELLDRV.OBJ" with a
corrected version. This correction is available from Novell Field
Service or from the Novell NetWare Center without cost. The new
driver is installed as follows:
1.Locate your working copy of the "GENSH-1" diskette.
2.Copy the new "SHELLDRV.OBJ" file into the "PCNET"
directory replacing the earlier version.
3.Re-link your workstation shells in the ordinary manner.
This will link new shells with the corrected driver.
4.Use these new shells and/or the NETBIOS emulator instead
of the old ones.
Santa Clara and Orchid Technology customers may receive correct
copies for their respective versions by contacting Orchid or Santa
Clara Systems.
/for